home *** CD-ROM | disk | FTP | other *** search
/ Cream of the Crop 3 / Cream of the Crop 3.iso / comm / ter12b.zip / TER12B._XE / DOCS.EXE / QUICK.DOC < prev    next >
Text File  |  1993-08-02  |  3KB  |  72 lines

  1.  
  2. ┌─────────────────────────────────────────────────────────────────────────────┐
  3. │ ░░░░ Getting started quickly ░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░ │
  4. └─────────────────────────────────────────────────────────────────────────────┘
  5.  
  6. For people who don't know much about serial communication and modems, we
  7. provide this small document, so you don't have to setup all kind of options.
  8.  
  9. Remember always: if you don't understand an option/feature, don't change the
  10. setting. All options have been set as sensible defaults for normal use, and 
  11. there is no immediate need to change options - although you will need to set 
  12. up the following things:
  13.  
  14. At startup you will be asked about which colorpalette you want to use.
  15. Terminate will check if you have a colorscreen and place cursor on color if
  16. present, just press enter and you are sure.
  17.  
  18. IMPORTANT: If you don't understand a toggle or option do not change it, just
  19.            leave as it was. All options have already been set to give best
  20.            performance for most people.
  21.  
  22. Terminal settings. If you have a faster modem than 2400 baud, you should
  23. set your baudrate to 19200 or 38400. Fast modems always use data compression
  24. and if you only use 9600, you will not be able to do fast transfers.
  25. For normal BBS use you should always use 8 databits, no parity, 1 stopbit.
  26. If you use 2400 you should disable Hardware RTS/CTS flowcontrol in the
  27. Terminal options menu. We always recommend that 9600 and faster modems, use
  28. hardware RTS/CTS flowcontrol, which is the safest way of sending data when
  29. using a speed to the comport at 19200 or above. Do never run 57600 baud on
  30. external modems, unless you are sure that your cable is protected from noise,
  31. try 38400 first. Remember you must also set RTS/CTS flowcontrol in you modem -
  32. look in the manual for the modem. RTS/CTS flowcontrol requires an internal
  33. modem OR an external and a correct modem cable which has the RTS and CTS 
  34. (Request to send/Clear to send) pins connected.
  35.  
  36. When you are finished with the basic configuration, you could move to the
  37. Modem & Dialing Menu and select a modem from Quick Install. But if your
  38. modem does not feature in the list, you must set the following things
  39. manually - or at least check if they work (Look in your modem manual to check 
  40. for further details. Remember factory defaults on your modem may mean you 
  41. won't have to change anything...):
  42.  
  43. Carrier Detect (CD) follows line (usually &C1)
  44.  
  45. Type AT&C1 and press enter
  46.  
  47. When DTR is low, line must be dropped, (Usually &D2 or &D3)
  48.  
  49. Type AT&D2 and press enter
  50.  
  51. Not all modems like this, if you can't hangup your modem, move to the
  52. Modem & dialing menu and Enter a 0 at the hang-up options which will
  53. allow Terminate to send a hangup string to your modem instead.
  54.  
  55. Type ATS0=0
  56. Then your modem will not pick up the phone leaving Terminate to make the 
  57. decision.
  58.  
  59. If you can save your setup in your modem, type AT&W, otherwise you must
  60. use the initstring: AT&C1&D2S0=0^M
  61.  
  62. If your modem string is not sent because the carrier is high when you
  63. start up Terminate, you should enable the switch FORCE INIT.
  64.  
  65. If your modem is a normal Hayes compatible you don't need to set up anything
  66. else, everything has been setup for this.
  67.  
  68. You could now press Alt-D for the phonebook and import or enter some entries
  69. - then you are ready to call a BBS system!
  70.  
  71.                                                          /The Author
  72.